What size supply duct for 3 ton unit - 5.2 Rectangular Ducts 7 5.3 Oval Ducts 8 6.0. SUPPLY DUCT CONFIGURATIONS 8 6.1 Extended Plenum Systems 8 6.2 Reducing Trunk System 10 ... ductwork is only increased by one standard size. ... The pressures are total pressure and include all losses through the air source unit, the supply ductwork, and the air terminals, return air grilles, and ...

 
Buy Goodman GPGM33608041 3 Ton Cooling / 80,000 BTU Heating, 13.4 SEER2 Packaged Unit. ... duct work. The packaged unit can also be easily converted to accommodate a plenum for normal or low-static applications. The Goodman packaged unit series are self-contained so the only connections needed for installation are the supply and return ducts .... Arsenic pentafluoride lewis structure

the duct system to be adequate for a .1 friction rate. • The chart should not be used to design complete duct systems. • To insure proper distribution of air, volume dampers must be used for all branch runs. • The chart is based on metal duct. Flex duct has a higher pressure drop and as such may require the size shown on this guide beThe Goodman ARUF29B14 air handler is rated for up to 2 tons. In some packages, the air handler will be slightly larger in tonnage than the condenser in the package. This is intentional, as it maintains the overall efficiency of the entire system. From the factory, the unit does need an outdoor unit to function as an AC or heat pump air handler ...System size - These units will be larger than the older system so here are the dimensions of the new system once assembled for the 2430. 56" H x 17.5" D x 25" W If the outdoor is a 3 ton, below are the model #'s to upgrade to: Blower - M3036BL1-EC2 Coil - M3036CL1-B or E - (which coil to use depends on the specific outdoor model.This series is avail-able in cooling Capacities of 2, 2 1⁄2, 3, 3 1⁄2, 4 and 5 nominal tons of cooling. Optional field installed heat kits are avail-able in 5,8,10,15 and 20 KW. The units can be easily in-stalled in manufactured or modular homes with existing high-static duct work.Run a large size plenum under home from Pkg unit. Run new branches to existing registers using six round 26ga pipe or insulated flex. Just slow, not stupid. ... on the master bedroom side. Shorten the helper up. So that it taps into the supply duct between the first supply for the master, and the last supply for the dining room. When posting in ...As far as the air goes. a 4 ton unit on medium is probably putting out 1400 to 1500 depending on yuor duct sizing. You need to size the bypass for the Total unit airflow, minus the smallest zone. So if your small 10" zone is around 300CFM. Then its unit T- Small zone= 1400-300=1100. You're probably somewhere in that neighborhood.However the main supply is only 18"x12" and runs 50 feet, it branches off to four 8x8 supplies on the 2nd floor, five 8x8 supplies on the first. By my calculations an 18"x12" main supply will only provide 430CFM or enough for a 1-ton system. So it looks like I would need 1400-1600CFM or something closer to 26"x26" or 28"x28".Forum Rules. I currently have a 3 ton with 16 inch metal return duct work. I was told this by a contractor: 3 ton heat pumps with the new r410a refrigerant recommended size is 18" on the return duct. Otherwise you should expect issues with your system typically in winter time. I wanted to verify with you guys since the cost of upsizing the ...Buy O General Duct Air Conditioner 3 TON ARGA36FMTA-U online at the best price in UAE from Sharaf DG. Shop from a large selection of Air Conditioners, Cooling & Heating, Home Appliances, Window Air ConditionersWe would like to show you a description here but the site won't allow us.The following duct sizes are based on a fraction drop of .10 inches per 100 feet of lineal duct. This "Equal-Friction" method of duct sizing should be adequate for normal residential furnace heating and air conditioning applications. Larger volumes or higher static pressures should be dealt with on an individual job basis.beenthere. 42671 posts · Joined 2008. #2 · Dec 31, 2009. Size of the supply run (duct), boot and register is determined by how much air you need. And what kind of throw the register is to give. Depending on model of floor register. It could allow an air delivery of 75 to 250CFM. Or 65 to 210 for a different type.What Size Supply Duct For a 4 Ton Unit When it comes to HVAC systems, the size and design of the supply ducts play a crucial role in ensuring proper airflow and efficient cooling or heating of a building. If you have a 4-ton unit, it is essential to select the appropriate size supply ducts…For 5-ton HVAC systems, an additional 6″ plenum on the bottom or the side of the furnace is super important. The reason? Airflow. With the additional 6″ plenum, you get more of it. It's true in all 5-ton systems, but several 4-ton systems also require the 6″ plenum.Goodman. MSRP: $2,995.00. Items 1 to 12 of 32 total. 1. 2. 3. Next. Air Conditioning Packaged Units for Sale, Rheem 3 Ton Package Unit - Budget Air Supply.HVAC Unit Sizing Chart with CFM per ton and starting supply and return size Notice that the CFM values in the above table are listed as a range. Whether your system flows at the minimum or the maximum of this range is dependent on the system’s friction loss as well as the equipment chosen.One contractor say to go with a 3.5 ton. One says 2.5 because of my small duct size. The ductwork measures 8 by 14 at the furnace but 6 by 10 inches at the wall vents. ... Your 34x8 supply duct seems to be the limiter at 3 1/2 tons. However, there could be other factors which may reduce that number. The contractor suggesting 2 1/2 tons very ...27 Apr 2013 ... 5 Ton HVAC unit short on return duct work. 56K views ... WHAT SIZE IS MY DUCTWORK? #ductwork #hvac ... Fiber Glass Duct: 3-Piece 90° Elbow (11/22).A furnace can move only so much air. Of course the number of registers will effect the airflow of each supply. Example: 1,200 cfm blower with 12 - 6" supplies equal (approx.) 100 cfm each. Add more supplies and the amount of airflow gets reduced. Most homes have more supplies than the blower can fully supply.System size - These units will be larger than the older system so here are the dimensions of the new system once assembled for the 2430. 56" H x 17.5" D x 25" W If the outdoor is a 3 ton, below are the model #'s to upgrade to: Blower - M3036BL1-EC2 Coil - M3036CL1-B or E - (which coil to use depends on the specific outdoor model.1.5 ton duct. i'm going to be installing a new duct system in the attic.900 sqft house 1.5 ton unit.total trunk line going to be about 20ft what size should my trunk line be? there will be about 6 6inch runs...thanks. To properly size your truckline you would have to calculate the duct size for your equipment.I wanna know what size duct work works with a 3 ton unit. Contractor's Assistant: I understand you're looking for information on the size of duct work that works with a 3 ton unit. Is this for a residential or commercial HVAC system? ... I suggest return be 25% larger than supply.20 X 14. It was my pleasure working with you today. Please ...Commercial Split Heat Pump Systems. Items 1 - 24 of 45. Sort By. Daikin 3 Ton 13 SEER Commercial Air Conditioner Condenser - 208/230V Three Phase. Model: DX13SA0363. $1,850.00. Daikin 3 Ton 13 SEER Commercial Air Conditioner Condenser - 460V Three Phase. Model: DX13SA0364. $1,925.00.†11/2 ton [5.3 kW] through 5 ton [17.6 kW] models are between 421/2 to 551/2 inches [1080 to 1410 mm] ... † Supply duct flanges provided as standard on air handler cabinet. ... appropriate unit size, voltage and number of electric heaters to be used. Make sure external static applied to unit allows oper-Based on the standard requirements for a 3-ton AC, you should get a return grille size that provides a minimum of 600 square inches. When manually measuring your return grille, take note of the general rule that you should have 200 square inches per ton. So, if you have a 3-ton unit, you should calculate for a grille with 600 square inches.HVAC ductwork sizing involves using a complex formula. To simplify things, here is a general overview of how ductwork size is calculated: (503) 673-9083 Schedule now. Get Filters. ... Cubic feet per minute is calculated by multiplying the size of the HVAC unit (in tons) by 400. Divide the answer by your home’s square footage to find out total ...Small Rooftop Units 3 to 15 Tons ... NUMBER USAGE MODEL SIZE TONNAGE SUPPLY AIR BRACKET SUPPLY AIR PICKUP TUBE RETURN AIR BRACKET RETURN AIR PICKUP TUBE CRSMKKIT003A00, CRSMKSEN003A00 48FC, 50FC, 50FCQ 04-07 3 to 6 48TC001809 (tube) ... ed to one or two compatible duct smoke sensors. The clearPull the airflow vertically to hit the friction loss line at 0.1 in.wg. Then, pull the line diagonally to the right and find the suitable duct diameter. 14″ round duct is less than ideal because the friction loss will be greater than 0.1 in.wg as the maximum airflow for 14″ round ducts is around 1027 cfm.October 9, 2023 by GEGCalculators. The size of a return air duct should generally be based on the HVAC system’s capacity. A common rule of thumb is to aim for approximately 400-450 CFM (cubic feet per minute) of airflow per ton of HVAC capacity. For example, a 2-ton system might require a return duct with a size of around 16 inches in diameter.Here's an example with the new ASHRAE duct size calculator. Our friction rate is 0.073 iwc/100′. ... 400 cfm at 0.073 iwc/100′ corresponds to a velocity of about 725 feet per minute (fpm). That's fine for supply ducts. To move 400 cfm on the return side in this duct system, we'd need to move to a larger duct. ... This would keep sound ...For the 3-ton, the CFM is 1200, given that 1 ton is equal to 400 CFMs. If this is the system you have, you should use a return and supply vent that matches the size of the AC in terms of the CFM it supports. If you use a small air filter than the system requires, you may also have a problem due to system cracks.Note: On July 1, 2017, Table 6.2.4.2. of Division B of the Regulation is amended by striking out "single dwelling units" in Column 1 of Item 1 and substituting "an individual dwelling unit in a building other than a house", striking out "Round" in Column 1 of Item 2 and substituting "Round ducts serving a house or an individual dwelling unit in a house" and striking out "for single dwelling ...Get More Results Design Services. Small-duct high-velocity heating and cooling designed to adapt to old homes, custom homes, and small spaces without compromising comfort, design or efficiency. Discover the Unico System, the perfect HVAC solution for homes, offering efficient, seamless installation and custom comfort for every homeowner.Apr 5, 2021 · Unless you select a square grille (such as a Cube Core with an Eggcrate design ), the size of the hole in the wall will not be the size of the grille you need. This is because a frame’s outer dimension adds roughly 2 inches to the overall size. For example, a 14x12 inch supply or return air grille with 16x14 inch dimensions will require a ... 3. Divide this number by 10 and you’ve calculated the airflow that your HVAC unit permits. 4. Multiply the length of your ducts with the width to calculate the duct size. As an example, if the size of your vent is five by nine inches, the CFM is 45 per vent. 5. Divide the CFM per duct by the complete amount of CFM of the furnace. 6.As illustrated in the above image. There are two main ducts (supply and return) which will go around the building to supply the various rooms. Coming off the supply duct is a round duct supplying the fan coil units. The fan coil units are connected to either a heating coil, a cooling coil or both heating and cooling coil. These will condition ...In order to meet my budget the installer has suggested I go with a Single 6-ton unit for my house instead of using a smaller split system (5-ton 3 1/2-ton) which he initally quoted. When I inquired the pro's and cons of a larger single unit he listed the following benefits: - less equipment to maintain. - less electic draw with single system.3. (wrong units) 325 CFM more generally needed for a 3-ton, so 3-ton VERY Likely Underperforming. ------ 1.46 square feet total should be adequate for 2-ton or ~ 50,000 BTU Output furnace/ 800 CFM with ~55'F Rise, BUT # of sharp turns significantly increase resistance and decreases air flow.Feb 19, 2024 · We have included charts for most of the popular standard air duct sizes. These include: Round flex duct: 5 inch – 20 inch. Metal round pipe: 5 inch – 20 inch. 4 inch rectangular duct: 6 inch – 24 inch diameter. 6 inch rectangular duct: 4 inch – 30 inch diameter. 8 inch rectangular duct: 4 inch – 36 inch diameter. 3. Q: How many sizes of units do you have? A: Currently, there are 4 systems available; a 1218 model with a nominal capacity of 1 to 1.5 tons (3.5 to 5.3 kW) system, a 2430 model with a nominal capacity of 2 to 2.5 tons ... The system requires only two types of duct – the main plenum and the supply tubing. The supply tubing is a 2 … In most cases, if you are installing ducts in each room where there is a supply, you will want to go with the same size as your supply vents. If you are installing just one or two return vents, you will want to go with a 12-inch return for 2-ton units and lower. 14- inches for 3 and up. 16-inch should be suitable for 4 ton systems, whereas 5 ... What Size Ductwork Do You Need for a 3-Ton Unit? For a three-ton unit, you will require an 18″ round air duct size for your ductwork. If you intend to use a rectangular air duct, you need a ductwork size of 16″x15″ to 40″x7″. ... The supply vent transfers air to your unit, which blows air into your living space.The high cost is $12,000 for a 3.5-ton packaged HVAC system with a SEER of 21 and moderate duct modifications. 3.5-Ton AC Unit Cost Calculator. 3.5-ton AC units are a fairly common size, used for homes averaging 2,000 to 2,200 sq.ft. They come in several types and efficiencies, impacting cost and quality.Round duct and rectangular duct comparison. A round duct with a cross sectional area of 0.6m2 has a perimeter of 2.75m. A rectangular duct with an equal cross sectional area has a perimeter of 3.87m. The rectangular duct therefore requires more metal for its construction, this adds more weight and costs to the design.Rectangular sheet metal duct = .07" on most metal duct calculators. 2900. 40x12. 100 31/2 x14 2200 38x10 220 31/2 x30 2350 40x10. Rectangular sheet metal duct = .07" on most metal duct calculators. 3050. 42x12.Feb 19, 2024 · The output from the calculator will give you up to 4 duct size options to choose from: 1 round size and up to 3 rectangular size options. The round duct size gives the size in diameter; The rectangular duct options give the width and height. You can choose 1 of the 4 sizes for your home based on what work best for its layout. What size should the trunk duct be for a 2 ton ac system? Updated: 9/19/2023. Wiki User. ∙ 13y ago. Best Answer. 14" Round or 14" x 12" Rec. will work.The size of the HVAC unit you'll need for the whole house can be found using the unit's average output and the square footage of your home. As a rule of thumb, you'll need 400 CFM of airflow per ton of air conditioning; it takes about 1 CFM of air to heat or cool 1 to 1.25 square feet of floor area. Last, you'll need to understand duct friction.Comfortmaker Ion™ CSH6 – The best single-stage 3-ton heat pump. With a cooling capacity that varies from 1.5 to 5 tons, the Comfortmaker Ion™ CSH6 heat pump is suitable for both small and large spaces. The unit features a single-stage scroll compressor and a single-speed fan motor that ensure stable output. Moreover, the CSH6 can switch ...This series is available in cooling Capacities of 2, 2 1⁄2, 3, 3 1⁄2, 4 and 5 nominal tons of cooling. Optional field installed heat kits are available in 5,8,10,15 and 20 KW. The units can be easily installed in manufactured or modular homes with existing high-static duct work.duct size If the duct was "properly sized" for a 3t system then no way will that duct be properly sized for a 3 1/2 t or a 4t system. Close may work! If the 3t was "properly sized" for the house then no way will " a large tonnage unit work properly.If the duct size was screwed up and the tonnage was also screwded up then maybe/might be.New condensor & coil will be 5 ton. Everything new except duct work. Existing duct work is in concrete floor and is sized 1600 cfm for a 4 ton unit. Current condensor & coil is 4 ton. House has always had problem cooling enough. House is 2,750 sq ft in hot Oklahoma with all brick and large large windows.What size of return duct do I need for a 3Ton HVAC air-handler. Answered in 4 minutes by: HVAC Technician: HVAC Guru. Hello, Typically a 16X20 would be fairly standard for most applications on a 3 ton unit. However if you want superior air flow I would highly suggest putting in a 20X20 as that gives you far better airflow hands down.Jul 1, 2015 · Asked Rick. “We usually use a 20 x 20 for 2.5 ton.”. Said the tech. 20 x 20 x 2 = 800. “800 CFM…Well that’s big enough for a 2 ton, but a 20 x 25 may be a better choice.”. 20 x 25 x 2 = 1000. “Wow,” said the tech, “I will have to start making some changes to my installs.”. “Don’t just take my word for it” said Rick. Lowering the fan speed will reduce the noise level, but the temperature of the air coming out of the coil will drop as the fan speed is reduced. You don't want it to get too low. Just as an example, in my system the air going in is at 75 F and coming out of the closest duct is 59 F. - Jim Stewart.As illustrated in the above image. There are two main ducts (supply and return) which will go around the building to supply the various rooms. Coming off the supply duct is a round duct supplying the fan coil units. The fan coil units are connected to either a heating coil, a cooling coil or both heating and cooling coil. These will condition ...Asked Rick. “We usually use a 20 x 20 for 2.5 ton.”. Said the tech. 20 x 20 x 2 = 800. “800 CFM…Well that’s big enough for a 2 ton, but a 20 x 25 may be a better …29 Apr 2013 ... Explaining what is an air duct calculator, how to size ... How to Design Duct Work for a 3 Ton Air Conditioning system ... How did we know when to ...The entire branch duct can be made of the sound attenuator (method A, Figure 2) or with 3 feet (1 m) of sound attenuator and the rest made of aluminum supply tubing (method B, Figure 2). For branch runs over 12-feet (3.6 m) long, method B recommend because the aluminum duct is stronger than the sound attenuator andA common rule of thumb for HVAC duct sizing is to have around 400 CFM per ton of cooling capacity. So, for a 5-ton unit, you would aim for 2000 CFM. How many CFM does a 3-inch pipe use?My 19yo AC (3.5 ton Trane) finally bit the dust and doing a complete system replacement though will likely leave most duct work. This unit serves our upstairs (about 2000 sq ft). A 2.5 ton serves our downstairs (about 1300 sq ft). Central NC. House has no shade and gets a lot of sun (dark roof, dark brick) and the attic naturally gets extremely ...Supply trunk (one continuous trunk) with: 8"x8" x 14' section with 3 - 6" supply branch runs. 8"x16" x 25' section with 6 - 6" supply branch runs. 8"x8" x 8' …Trunk/supply duct sizes 3 ton to 2 ton. When I moved it, I had a 3 ton system with only 5 supply ducts (6" flex). The static pressure caused a windstorm in each room. I had two more supply ducts added, and the rest of them increased to a larger size (probably 9" or 10" flex) to lower the static pressure.What Size Ducts Should My Return Air Be? The size of return air ducts should be based on the size of the heating and cooling system that they are connected …1.5 ton duct. i'm going to be installing a new duct system in the attic.900 sqft house 1.5 ton unit.total trunk line going to be about 20ft what size should my trunk line be? there will be about 6 6inch runs...thanks. To properly size your truckline you would have to calculate the duct size for your equipment.What I gather, is that duct work is designed around the a/c unit cfms. My house needs a 1.5 ton air conditioner (18k heat gain) and at 400 cfm/ton is 600cfms. My current sized trunk would have the 600 cfms in mind and then reduce from there correctly. My load cal program also gives the cfm/room and suggested duct sizes.A plenum is a distribution box attached to the supply outlet of the air handling unit. And the purpose of plenum box is to distribute the cooled or heated air to several spaces. It is also used to balnce the air and attenuate the sound caused by …Location. North Richland Hills, Texas. Posts. 15,732. Post Likes. 3/4 should be allowable with every manufacturers 3 ton R-410A system, and is the recommended size for some. It won't void any warranties, and the 200-400 btuh of capacity difference will never make up for the cost of the refrigerant lines.The neck size of supply air diffusers is always 50mm less than the height of the associated duct. For example, if you have a branch duct with a size of 400x300mm, you can't connect it to a supply air diffuser with a neck size of 300mm in diameter because the height of the branch duct is only 300mm and there is not enough space to install a ...Round duct and rectangular duct comparison. A round duct with a cross sectional area of 0.6m2 has a perimeter of 2.75m. A rectangular duct with an equal cross sectional area has a perimeter of 3.87m. The rectangular duct therefore requires more metal for its construction, this adds more weight and costs to the design. unit, and reasonable length duct runs. Most technicians are skeptical about these numbers, especially on the Return air side of the system. For instance a 2.5 ton system (Approximately 400 CFM per ton) would require (2) 14” flexible return ducts or (1) very short flexible 18” duct to move the 1000 CFM required by the 2.5 ton system. The following sizes are what are commonly required for line sets. The first number is for the outside diameter (OD) of the copper liquid line, and the second number is for the OD of the suction line. Note that this is not the inside diameter of the lines. 1/4" x 3/8". 1/4" x 1/2". 1/4" x 5/8". 3/8" x 5/8".Share This Guide. What Size Return Duct for 3.5, 4, 5 ton AC? How to Calculate Return Air Duct Size? For a Rectangular Return Duct. For a Circular Return Duct. What Size Return Duct for 3.5 ton …Originally Posted by tigergrad97. 12" -14"...by appearance anyway. 2-14" would be ok for 3 tons (depending on length and bends/turns. So your a bit small for 3 tons if 1 is 12" and the other 14". Which may be why your current 3 ton struggles on some days. Reply. 11-10-2010, 09:09 PM #10. tedkidd. Professional Member*.A 3 Ton air conditioner is typically necessary for homes up to 1,500 to 2,500 square feet. Other factors such as climate, home insulation, and number of windows can also influence the right air conditioner size for your home, so be advised that this is just a general example. For a slightly smaller home you might want to consider a 2.5 ton unit.1. Yes, my “Ductulator” says a 12” diameter duct (with insulation on the exterior of the duct) is a little small, but barely adequate for a 2 ton unit. If I was sizing it I’d use a 14” diameter with a friction loss of .09 per 100 feet of duct on the SUPPLY side and .07 on the RETURN side. However, your 12” duct will make the air ...Buy Goodman GPC1460M41 5 Ton, 14 SEER Self-Contained Packaged Air Conditioner, Multi-Position. ... Supply Air Opening Size. side 16w x 18h bottom 22w x 11d Inches. Return Air Opening Size. ... 50" x 53" x 3" Condensing Unit Pad $239.99. Add to Cart. Thermostats. Cielo Smart Thermostat Eco ...The size of the return air duct you would be getting for your 5-ton unit depends on if you would want a round or rectangular duct; the timely round return for your 5-ton unit is 2” in diameter, while for a rectangular duct, you would need a duct of 20” ×18” width by height. Using the correct duct size for your device would save you from ...Drain Pipe Connection Size inch 3/4 Rooftop Packaged Unit COOL ONLY 50ZPM-36A9 50ZPM-48A9 50ZPM-60A9 Unit Size Cooling TR 3.0 4.0 5.0 Rated Capacity 1 BTU/h 36,000 48,000 56,000 ... cooling unit with horizontal supply and return ducts. The 50ZP units are available in three standard cooling sizes to meet residential and light commercial ...that duct needs to be upsized to flow at 900 to 1,100 fpm. that will drop the static pressure noticeably ... how much depends on the length of the main supply duct and size of the other ducts.. Supply duct size coming off of the 12 x 19" opening at 4,000 cfm needs to have an inside area of 1.8 to 2 square feet. with a total equivalent length of ...Gree's High Lift design allows for extended piping length, up to 262 feet total, as well as 50 feet of vertical lift from the condensing units. This allows for greater flexibility in the layout of the system. Allows up to 262 feet of pipe length. Outdoor Unit Indoor Unit Power Supply Transmission System. Energy Saving.Jul 29, 2022 · Return air duct size for 1-5 ton ACs is 14” to 22” for round ducts and 13”x12” to 32”x12” for rectangular ducts. Use the return air duct size calculator below for accurate dimensions required for your air conditioner or heat pump.

When it comes to keeping your home comfortable, an appropriately sized air conditioning unit is crucial. If your AC unit is too small, it won’t be able to cool your space effective.... Lowes ina road

what size supply duct for 3 ton unit

3. Divide this number by 10 and you’ve calculated the airflow that your HVAC unit permits. 4. Multiply the length of your ducts with the width to calculate the duct size. As an example, if the size of your vent is five by nine inches, the CFM is 45 per vent. 5. Divide the CFM per duct by the complete amount of CFM of the furnace. 6.It's a two ton unit and I can't figure out how to size the plenum. The Air handler is central in the attic, only 6 runs so I'm going to do a radial duct system. Example. System Info-. 2 ton system with supply air opening of 16.375 x 11.3 Inches. 6 flex duct runs total; 5 8" runs 1 4" run. Longest run is 15 feet. 1.Fan Coil Units. ENVIRO-TEC fan coil units are designed to exceed the stringent quality standards of the institutional market, while remaining cost competitive in the light commercial segment of the market. A variety of models - each with an extensive list of standard features - allows unparalleled design flexibility.If desired, you can connect your unit to a fresh air fan or duct to supply fresh air into the space you're conditioning. All mini-split concealed duct units feature a condensate removal pump that removes water resulting from the cooling of warm, humid air. You will need to attach a drain pipe or PVC to the pump in order to drain the condensate.So if you go 25% bigger, I'd expect to notice much improvement in capacity & efficiency you'd certainly need more duct and register capacity. I'd bet staying 2 ton and having the duct system checked and improved would be all you need. Reply. 08-02-2013, 08:27 PM #7. kangaroogod.Best Place for Supply Air Vents. The best location for the supply vent is on the wall, right under the window opening. However, ceiling installation and floor installations also work a treat as long as your heating system has sufficient BTUh capacity and fan. The location of the air ducts may limit your choice.The cfm should be matched to the condensing unit. 1200 cfm max for your 3 ton unit. Even at 1600 cfm your temp rise should still be up around 17 deg, so either the system isn't performing well or you're taking inaccurate measurements. 1350 is fine for a heat pump, in heating mode. 1600 a bit too much.Using another calculator, I have 8000 sqft of total air volume with 6 changes an hour which suggests a 2.5 ton system, but since I already have the spec saying 1025 …The rectangular return duct size for a 2-ton AC unit ranges from 182 square inches to 216 square inches, while the circular return duct size is 14 in diameter. For the same AC unit, rectangular ducts of different widths are acceptable as long as their total square inches are approximately equal. In most cases, the required CFM per ton is 400 ...A dedicated outdoor air system (DOAS) is a unit supplying cooled, dehumidified outside air to a building in the summer and heated outside air in the winter. Greenheck's comprehensive line of outdoor air units is designed to meet a wide range of heating, cooling, dehumidification, and ventilation requirements. These rooftop units deliver up to 100% outside air and are ideal for any variable ...What I gather, is that duct work is designed around the a/c unit cfms. My house needs a 1.5 ton air conditioner (18k heat gain) and at 400 cfm/ton is 600cfms. My current sized trunk would have the 600 cfms in mind and then reduce from there correctly. My load cal program also gives the cfm/room and suggested duct sizes.In a rule of thumb sense the return duct should be the same size as all the supply ducts combined. But a rule of thumb is just an initial guide, not anything to bet your comfort on. You have to consider the length of duct and the type of duct. HVAC engineers have developed manuals to cover all the ins and outs of how to size duct work.In short, there's two prevailing standards that determine whether duct detection is required. The first (and most common in the United States), is the International Mechanical Code (IMC). Section 606.2 identifies areas where smoke detection is required for the purpose of mechanical unit shutdown. The other prevailing standard is NFPA …Other Airflow Units Like L/Min Or Cubic Meters Per Hour. CFM is an imperial unit, commonly used in the US. If you are using other units, like l/min or m 3 /h, you can use these unit-to-unit relations to translate other units in CFM. 1 CFM = 1.699 m 3 /h 1 CFM = 28.317 l/minuteSep 30, 2021 · September 30, 2021. Sky Heating’s HVAC Ductwork Sizing Guide. The right sized ductwork ensures your HVAC system will work efficiently. If the ducts are too small, the system will work harder and use more energy; oversized ducts will reduce air velocity, and you might not know air is venting into rooms. HVAC ductwork sizing involves using a ... 2 Nominal heating capacities are based on the following conditions: Return air temperature: 70°FDB. Outdoor temperature: 47°FDB, 43°FWB Equivalent ref. piping: 25ft (Horizontal) 3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat..